Ext. No 0 / Ext. Id. 0 SIMPLE = T / file does conform to FITS standard BITPIX = -32 / number of bits per data pixel NAXIS = 1 / number of data axes NAXIS1 = 1080 / length of data axis 1 EXTEND = T / FITS dataset may contain extensions COMMENT FITS (Flexible Image Transport System) format defined in Astronomy and COMMENT Astrophysics Supplement Series v44/p363, v44/p371, v73/p359, v73/p365. COMMENT Contact the NASA Science Office of Standards and Technology for the COMMENT FITS Definition document #100 and other FITS information. COMMENT DATE = '03/05/02' / FITS file creation date (dd/mm/yy) TITLE = 'GOLF_1 ' / FICHIER TELEMESURE LEVEL = 1 / NIVEAU D ANALYSE TELESCOP= 'SOHO ' / ESA/NASA Solar orbital observatory INSTRUME= 'GOLF ' / Global oscillations at low frequencies CHANNEL = 'FSmain ' / canal en usage PROGRAM = 'ecritfits1_cd' / nom du programme qui a cree le fichier VERSION = 'Wed Sep 22 15:03:06 1999' / creation du code executable AUTHOR = 'C.Renaud-G.Grec' / ORIGIN = 'Observatoire de Nice' / HOTE = 'rota ' / ordinateur utilise pour creer ce fichier USER = 'renaud ' / utilisateur du programme CALIBR = '************************' / edition des calibrations COMMENT MESURES EN VOL COMMENT DAT_OBS = ' 1/ 5/ 2' / date de la mesure (j/m/a) COMMENT temps de reference pour LOBT : TAI horloge de bord COMMENT Debut du fichier a LOBT = 0 heure COMMENT Fin du fichier a LOBT = 24 heures UT_TAI0 = -2.90E+01 / valeur de UT a TAI=0h00:00 en sec. DELOBS = 5.00E+00 / retard des observations au sol en sec TIMESTEP= '80 secondes' / cycle de base Golf COMMENT La premiere table contient un test END ______________________________________________________ Ext. No 1 / Ext. Id.JOURNAL DE L ETAT DE L EXPERIENCE XTENSION= 'TABLE ' / ASCII table extension BITPIX = 8 / 8-bit ASCII characters NAXIS = 2 / 2-dimensional ASCII table NAXIS1 = 72 / width of table in characters NAXIS2 = 64 / nombre de lignes utilisees PCOUNT = 0 / no group parameters (required keyword) GCOUNT = 1 / one data group (required) TFIELDS = 1 / number of fields in each row TBCOL1 = 1 / beginning column of field 1 TFORM1 = 'A72 ' / Fortran-77 format of field EXTNAME = 'JOURNAL DE L ETAT DE L EXPERIENCE' / name of this ASCII table extensi CHANNEL = 'FSmain ' / canal en usage COMMENT partie 1 - Etat de l'experience COMMENT partie 2 - Liste des telecommandes COMMENT partie 3 - Liste des changements d'etat END ______________________________________________________ Ext. No 2 / Ext. Id.NUMERO DE BLOC GOLF,STATUS ET TEMPS LOBT XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 10 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 5 / number of fields in each row TTYPE1 = 'numero de bloc golf' / label for field 1 TFORM1 = '1I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'unsigned number' / physical unit of field TTYPE2 = 'LOBT1 (msb),unsigned' / label for field 2 TFORM2 = '1I ' / data format of the field: 2-byte INTEGER TUNIT2 = '65536 secondes' / physical unit of field TTYPE3 = 'LOBT2, unsigned' / label for field 3 TFORM3 = '1I ' / data format of the field: 2-byte INTEGER TUNIT3 = 'secondes' / physical unit of field TTYPE4 = 'LOBT3 (lsb),unsigned' / label for field 4 TFORM4 = '1I ' / data format of the field: 2-byte INTEGER TUNIT4 = 'seconde/65536' / physical unit of field TTYPE5 = 'status telemetrie' / label for field 5 TFORM5 = '1I ' / data format of the field: 2-byte INTEGER TUNIT5 = 'unsigned number' / physical unit of field EXTNAME = 'NUMERO DE BLOC GOLF,STATUS ET TEMPS LOBT' / name of this binary table COMMENT LOBT=jour julien, temps=0 @ 0h 1 jan 58 MISSING = 0 / REMARK: apply only to the status data END ______________________________________________________ Ext. No 3 / Ext. Id.TABLE DES COMPTAGES DU PM1 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 64 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'comptages, it=0a15' / label for field 1 TFORM1 = '16E ' / data format of the field: 4-byte REAL TUNIT1 = 'coups par seconde' / physical unit of field EXTNAME = 'TABLE DES COMPTAGES DU PM1' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 reels 32 bits COMMENT une ligne contient les 16 comptages d'un cycle de 80 sec MISSING = -1.0000000E+06 / marquage des mesures non recues END ______________________________________________________ Ext. No 4 / Ext. Id.TABLE DES COMPTAGES DU PM2 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 64 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'comptages, it=0a15' / label for field 1 TFORM1 = '16E ' / data format of the field: 4-byte REAL TUNIT1 = 'coups par seconde' / physical unit of field EXTNAME = 'TABLE DES COMPTAGES DU PM2' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 reels 32 bits COMMENT une ligne contient les 16 comptages d'un cycle de 80 sec MISSING = -1.0000000E+06 / marquage des mesures non recues END ______________________________________________________ Ext. No 5 / Ext. Id.COMPTAGES VOIE SPECTRE DU PM1 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 64 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'comptages, it=0a15' / label for field 1 TFORM1 = '16E ' / data format of the field: 4-byte REAL TUNIT1 = 'coups par seconde' / physical unit of field EXTNAME = 'COMPTAGES VOIE SPECTRE DU PM1' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 reels 32 bits COMMENT une ligne contient les 16 comptages d'un cycle de 80 sec MISSING = -1.0000000E+06 / marquage des mesures non recues END ______________________________________________________ Ext. No 6 / Ext. Id.COMPTAGES VOIE SPECTRE DU PM2 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 64 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'comptages, it=0a15' / label for field 1 TFORM1 = '16E ' / data format of the field: 4-byte REAL TUNIT1 = 'coups par seconde' / physical unit of field EXTNAME = 'COMPTAGES VOIE SPECTRE DU PM2' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 reels 32 bits COMMENT une ligne contient les 16 comptages d'un cycle de 80 sec MISSING = -1.0000000E+06 / marquage des mesures non recues END ______________________________________________________ Ext. No 7 / Ext. Id.POSITIONS DU MOTEUR POLARISEUR XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GXPOANG, it=0,15' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'POSITIONS DU MOTEUR POLARISEUR' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 positions d'un cycle de 80 sec COMMENT codage des positions moteurs sur 15 bits COMMENT valeur negative si la fin du mouvement est anormale MISSING = 32768 / marquage des mesures non recues OFFSET = 0.0000000E+00 / position pour 0 binaire GAIN = 1.0986328E-02 / valeur du bit en degre END ______________________________________________________ Ext. No 8 / Ext. Id.POSITIONS DU MOTEUR QUART D ONDE XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GXQWANG, it=0,15' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'POSITIONS DU MOTEUR QUART D ONDE' / name of this binary table extensi COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 positions d'un cycle de 80 sec COMMENT codage des positions moteurs sur 15 bits COMMENT valeur negative si le bit de fin du mouvement est anormal MISSING = 32768 / marquage des mesures non recues OFFSET = 0.0000000E+00 / position pour 0 binaire GAIN = 1.0986328E-02 / valeur du bit en degre END ______________________________________________________ Ext. No 9 / Ext. Id.TEMPERATURE FINE QUEUSOT XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GTCSFIN, it=0,15' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'TEMPERATURE FINE QUEUSOT' / name of this binary table extension COMMENT sonde platine COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 mesures d'un cycle de 80 sec COMMENT codage des mesures sur 14 bits MISSING = 65535 / marquage des mesures non recues OFFSET = 1.6892999E+02 / temperature pour 0 binaire GAIN = 9.7631253E-03 / facteur de conversion du binaire en degre END ______________________________________________________ Ext. No 10 / Ext. Id.TEMPERATURE FINE FILTRE (sonde platine) XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GTFIFIN, it=0,16' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'TEMPERATURE FINE FILTRE (sonde platine)' / name of this binary table COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 mesures d'un cycle de 80 sec MISSING = 65535 / marquage des mesures non recues COMMENT codage des mesures sur 14 bits OFFSET = 3.4999999E-01 / temperature pour 0 binaire GAIN = 9.7435899E-03 / facteur de conversion du binaire en degres Cels END ______________________________________________________ Ext. No 11 / Ext. Id.TEMPERATURE CATHODES PM1 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GTPM1FIN, it=0,15' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'TEMPERATURE CATHODES PM1' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 mesures d'un cycle de 80 sec COMMENT codage des mesures sur 14 bits MISSING = 65535 / marquage des mesures non recues OFFSET = 1.4580000E+01 / temperature Celsius pour 0 binaire GAIN = 4.9035409E-03 / conversion valeur binaire en degre Celsius END ______________________________________________________ Ext. No 12 / Ext. Id.TEMPERATURE CATHODES PM2 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GTPM2FIN, it=0,15' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'TEMPERATURE CATHODES PM2' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 mesures d'un cycle de 80 sec COMMENT codage des mesures sur 14 bits MISSING = 65535 / marquage des mesures non recues OFFSET = 1.4350000E+01 / temperature Celsius pour 0 binaire GAIN = 4.9035409E-03 / conversion valeur binaire en degre Celsius END ______________________________________________________ Ext. No 13 / Ext. Id.TEMPERATURE AIMANT XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 32 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GTMAGFIN, it=0,15' / label for field 1 TFORM1 = '16I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'valeurs binaires' / physical unit of field EXTNAME = 'TEMPERATURE AIMANT' / name of this binary table extension COMMENT pour chaque jour 1080 lignes de 16 entiers 16 bits COMMENT une ligne contient les 16 mesures d'un cycle de 80 sec MISSING = 65535 / marquage des mesures non recues COMMENT codage des mesures sur 14 bits OFFSET = 1.0730000E+01 / temperature Celsius pour 0 binaire GAIN = 9.7802198E-03 / conversion valeur binaire en degre Celsius END ______________________________________________________ Ext. No 14 / Ext. Id.TEMPERATURES PRELEVEES 2 FOIS PAR CYCLE XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 76 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 19 / number of fields in each row TTYPE1 = 'GTPOELT ' / label for field 1 TFORM1 = '2I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'binaire ' / physical unit of field TTYPE2 = 'GTPOMEC ' / label for field 2 TFORM2 = '2I ' / data format of the field: 2-byte INTEGER TUNIT2 = 'binaire ' / physical unit of field TTYPE3 = 'GTSCREEN' / label for field 3 TFORM3 = '2I ' / data format of the field: 2-byte INTEGER TUNIT3 = 'binaire ' / physical unit of field TTYPE4 = 'GTFIRAD ' / label for field 4 TFORM4 = '2I ' / data format of the field: 2-byte INTEGER TUNIT4 = 'binaire ' / physical unit of field TTYPE5 = 'GTFIHOUS' / label for field 5 TFORM5 = '2I ' / data format of the field: 2-byte INTEGER TUNIT5 = 'binaire ' / physical unit of field TTYPE6 = 'GTFIELT ' / label for field 6 TFORM6 = '2I ' / data format of the field: 2-byte INTEGER TUNIT6 = 'binaire ' / physical unit of field TTYPE7 = 'GTPM1ELT' / label for field 7 TFORM7 = '2I ' / data format of the field: 2-byte INTEGER TUNIT7 = 'binaire ' / physical unit of field TTYPE8 = 'GTHV1 ' / label for field 8 TFORM8 = '2I ' / data format of the field: 2-byte INTEGER TUNIT8 = 'binaire ' / physical unit of field TTYPE9 = 'GTPM2ELT' / label for field 9 TFORM9 = '2I ' / data format of the field: 2-byte INTEGER TUNIT9 = 'binaire ' / physical unit of field TTYPE10 = 'GTHV2 ' / label for field 10 TFORM10 = '2I ' / data format of the field: 2-byte INTEGER TUNIT10 = 'binaire ' / physical unit of field TTYPE11 = 'GTCB ' / label for field 11 TFORM11 = '2I ' / data format of the field: 2-byte INTEGER TUNIT11 = 'binaire ' / physical unit of field TTYPE12 = 'GTREARAD' / label for field 12 TFORM12 = '2I ' / data format of the field: 2-byte INTEGER TUNIT12 = 'binaire ' / physical unit of field TTYPE13 = 'GTCLEAK ' / label for field 13 TFORM13 = '2I ' / data format of the field: 2-byte INTEGER TUNIT13 = 'binaire ' / physical unit of field TTYPE14 = 'GTCS ' / label for field 14 TFORM14 = '2I ' / data format of the field: 2-byte INTEGER TUNIT14 = 'binaire ' / physical unit of field TTYPE15 = 'GTHSKELT' / label for field 15 TFORM15 = '2I ' / data format of the field: 2-byte INTEGER TUNIT15 = 'binaire ' / physical unit of field TTYPE16 = 'GTDPU ' / label for field 16 TFORM16 = '2I ' / data format of the field: 2-byte INTEGER TUNIT16 = 'binaire ' / physical unit of field TTYPE17 = 'GTPSU ' / label for field 17 TFORM17 = '2I ' / data format of the field: 2-byte INTEGER TUNIT17 = 'binaire ' / physical unit of field TTYPE18 = 'GTQWELT ' / label for field 18 TFORM18 = '2I ' / data format of the field: 2-byte INTEGER TUNIT18 = 'binaire ' / physical unit of field TTYPE19 = 'GTQWMEC ' / label for field 19 TFORM19 = '2I ' / data format of the field: 2-byte INTEGER TUNIT19 = 'binaire ' / physical unit of field EXTNAME = 'TEMPERATURES PRELEVEES 2 FOIS PAR CYCLE' / name of this binary table COMMENT les mesures manquantes sont forcees a ffff hexadecimal MISSING = 65535 / marquage des mesures non recues OFFSET1 = -1.4450000E+01 / temperature Celsius pour 0 binaire OFFSET2 = -1.4250000E+01 / temperature Celsius pour 0 binaire OFFSET3 = -1.4400000E+01 / temperature Celsius pour 0 binaire OFFSET4 = -3.9049999E+01 / temperature Celsius pour 0 binaire OFFSET5 = -1.5150000E+01 / temperature Celsius pour 0 binaire OFFSET6 = -1.5330000E+01 / temperature Celsius pour 0 binaire OFFSET7 = -1.4750000E+01 / temperature Celsius pour 0 binaire OFFSET8 = -1.3240000E+01 / temperature Celsius pour 0 binaire OFFSET9 = -1.3100000E+01 / temperature Celsius pour 0 binaire OFFSET10= -1.4570000E+01 / temperature Celsius pour 0 binaire OFFSET11= -2.3999999E-01 / temperature Celsius pour 0 binaire OFFSET12= -1.3400000E+01 / temperature Celsius pour 0 binaire OFFSET13= -1.3050000E+01 / temperature Celsius pour 0 binaire OFFSET14= -8.0000001E-01 / temperature Celsius pour 0 binaire OFFSET15= -1.3150000E+01 / temperature Celsius pour 0 binaire OFFSET16= -1.4050000E+01 / temperature Celsius pour 0 binaire OFFSET17= -1.4050000E+01 / temperature Celsius pour 0 binaire OFFSET18= -1.5350000E+01 / temperature Celsius pour 0 binaire OFFSET19= -1.4850000E+01 / temperature Celsius pour 0 binaire GAIN1 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN2 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN3 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN4 = 1.7338218E-02 / conversion valeur binaire en degre Celsius GAIN5 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN6 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN7 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN8 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN9 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN10 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN11 = 5.2461538E-02 / conversion valeur binaire en degre Celsius GAIN12 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN13 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN14 = 5.2459098E-02 / conversion valeur binaire en degre Celsius GAIN15 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN16 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN17 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN18 = 1.7076923E-02 / conversion valeur binaire en degre Celsius GAIN19 = 1.7076923E-02 / conversion valeur binaire en degre Celsius COMMENT 1080 lignes pour chacune des 19 variables definies, COMMENT chaque ligne contient les 2 mesures de chaque cycle de 80 sec END ______________________________________________________ Ext. No 15 / Ext. Id.VOLTAGES DES ALIMENTATIONS XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 10 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 5 / number of fields in each row TTYPE1 = 'Gplus28 ' / label for field 1 TFORM1 = 'I ' / data format of the field: 2-byte INTEGER TUNIT1 = 'binaire ' / physical unit of field TTYPE2 = 'Gplus5 ' / label for field 2 TFORM2 = 'I ' / data format of the field: 2-byte INTEGER TUNIT2 = 'binaire ' / physical unit of field TTYPE3 = 'Gmoins5 ' / label for field 3 TFORM3 = 'I ' / data format of the field: 2-byte INTEGER TUNIT3 = 'binaire ' / physical unit of field TTYPE4 = 'Gplus15 ' / label for field 4 TFORM4 = 'I ' / data format of the field: 2-byte INTEGER TUNIT4 = 'binaire ' / physical unit of field TTYPE5 = 'Gmoins15' / label for field 5 TFORM5 = 'I ' / data format of the field: 2-byte INTEGER TUNIT5 = 'binaire ' / physical unit of field EXTNAME = 'VOLTAGES DES ALIMENTATIONS' / name of this binary table extension COMMENT les mesures manquantes sont forcees a 8000 hexadecimal MISSING = 65535 / marquage des mesures non recues OFFSET1 = 7.0000000E+01 / tension en Volt pour 0 binaire OFFSET2 = -6.2500000E+00 / tension en Volt pour 0 binaire OFFSET3 = -6.2500000E+00 / tension en Volt pour 0 binaire OFFSET4 = -1.8725000E+01 / tension en Volt pour 0 binaire OFFSET5 = -1.8725000E+01 / tension en Volt pour 0 binaire GAIN1 = -3.4188036E-02 / conversion valeur binaire en Volt GAIN2 = 3.0525031E-03 / conversion valeur binaire en Volt GAIN3 = 3.0525031E-03 / conversion valeur binaire en Volt GAIN4 = 9.1452990E-03 / conversion valeur binaire en Volt GAIN5 = 9.1452990E-03 / conversion valeur binaire en Volt COMMENT 1080 lignes pour chacune des 5 variables definies, COMMENT chaque tension est mesuree une fois sur chaque cycle de 80 sec END ______________________________________________________ Ext. No 16 / Ext. Id.SEUIL DISCRI SPECTRE DU PM1 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 1 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GUSP1DAC' / label for field 1 TFORM1 = 'B ' / data format of the field: BYTE TUNIT1 = 'binaire ' / physical unit of field EXTNAME = 'SEUIL DISCRI SPECTRE DU PM1' / name of this binary table extension COMMENT tableau de 1080 valeurs COMMENT une valeur pour chaque cycle de 80 sec MISSING = 0 / marquage des mesures non recues OFFSET = 0.0000000E+00 / seuil en mVolt pour 0 binaire GAIN = 4.9803920E+00 / conversion valeur binaire en mVolt END ______________________________________________________ Ext. No 17 / Ext. Id.SEUIL DISCRI SPECTRE DU PM2 XTENSION= 'BINTABLE' / binary table extension BITPIX = 8 / 8-bit bytes NAXIS = 2 / 2-dimensional binary table NAXIS1 = 1 / width of table in bytes NAXIS2 = 1080 / number of rows in table PCOUNT = 0 / size of special data area GCOUNT = 1 / one data group (required keyword) TFIELDS = 1 / number of fields in each row TTYPE1 = 'GUSP2DAC' / label for field 1 TFORM1 = 'B ' / data format of the field: BYTE TUNIT1 = 'binaire ' / physical unit of field EXTNAME = 'SEUIL DISCRI SPECTRE DU PM2' / name of this binary table extension COMMENT tableau de 1080 valeurs COMMENT une valeur pour chaque cycle de 80 sec MISSING = 0 / marquage des mesures non recues OFFSET = 0.0000000E+00 / seuil en mVolt pour 0 binaire GAIN = 4.9803920E+00 / conversion valeur binaire en mVolt END ______________________________________________________